NM20

NM20 Motor Protection Relay


The NM20 protection relay can be used for protecting large asynchronous and synchronous motors on MT networks, applicable for lines of any length in systems with isolated neutrals, solidly grounded, Petersen coil and/or resistance grounded.

Features of the NM20 Motor Protection Relay

Its standard and control features include management of undervoltage and positive sequence undervoltage, directional active underpower, and regulation of under current It also offers detection of loss offield, Negative sequence overvoltagefor motors and generators, control of the maximum number of startings with the possibility of inhibiting restart, and ground directionality.
Thytronic's NM20 relay also monitors over- and underfrequency, breaker operation, and the trip circuit. Additionally, it provides the option to integrate thermal protection function 26 for measuring machine temperature via Pt100 thermometric probes. Hardware and software configuration options offer further customization possibilities.


FUNCTIONS


STANDARD PROTECTIVE & CONTROL ELEMENTS

  • Sequence of Fault Recorder (SFR)
  • Sequence of event Recorder (SER)
  • Positive Sequence Undervoltage - 27V1
  • Phase overcurrent side H and side L - 50/51
  • Overfrequency - 81O
  • Underfrequency - 81U
  • Residual Overvoltage - 59N
  • VT Supervision - 74VT
  • Ground directional overcurrent - 67N
  • Overvoltage - 59
  • CT Supervision - 74CT
  • Under Voltage - 27
  • Directional active underpower - 37P
  • Maximum number of startings (Restart inhibition) - 66
  • Under Current - 37
  • Breaker Failure - BF
  • Negative sequence overvoltage - 59V2
  • Loss of Field - 40
  • Maximum Residual Overcurrent - 50N/51N(1)
  • Minimum Power Factor - 55
  • Trip Circuit Supervision - 74TCS

SW PACK OPTIONAL CONFIGURATION

  • Digital Fault Recorder (DFR)
HW PACK OPTIONAL CONFIGURATION
  • Thermal with Pt100 Probes - 26

COMMUNICATION FUNCTIONS

  • Modbus TCP-IP
  • One USB Type B local port for communication with ThyVisor setup software
  • Modbus protocol RTU RS485 / IEC 870-5-103 / DNP3
  • IEC61850 Ed.1 & Ed. 2

DOWNLOADS

Flyer NM20
Coding Sheet NM20
PRO-N NM20 IEC 61850 Certificate
NM20 Manual